| Mechanical
Specifications: |
| |
Master
and Passive Posts: |
|
| |
Material |
Posts:
250 x 150 x 5mm thick steel RHS |
|
| |
Base
Plate |
350
x 350 x 12mm thick steel plate |
|
| |
Height |
840mm |
|
| |
Weight |
Master
Post: 58 kg (including Main Operating Module and Batteries)
Passive Post: 38 kg (including Counterweight Arm) |
|
| |
Treatment |
Heavy
zinc plated (inside and out) and powder coated
Colour: Standard - brilliant white. Optional - other colours
from Colourbond® range |
|
| |
Main
Cable: |
|
| |
Material |
Grade
304 Stainless Steel, 7/19 Lay, 8mm diameter |
|
| |
|
|
|
| Operating
Specifications: |
| |
Opening
Time
Closing Time |
Approximately
0.5 second
Approximately 7 seconds
|
|
| |
|
|
|
| Installation
Specifications: |
| |
Cable
Span Range |
4.0
metres to 8.0 metres
|
|
| |
Operating
Temperature Range |
-10ºC
to +50ºC |
|
| |
Post
Anchoring |
Four
20mm x 260mm Chemical Anchor threaded rods with nuts and washers
per post
OR
One 20mm x 300mm square Bolt Cage Assembly (280mm centres)
with nuts and washers per Post. |
|
| |
|
|
|
| Electrical
Specifications: |
|
Primary
Power Source
|
2
x 7Ah 12v rechargeable SLA Batteries |
|
| |
Battery
Charging System |
Integrated
into the Gate control system
|
|
| |
Plug
Pack |
24-Volt
1 amp AC Plug Pack |
|
| |
Solar
Panel Charging |
20w
to 160w depending on installation location and daily cycle
rate. (Optional) |
|
| |
|
|
|
| Control
System Specifications |
| |
Access
Control System Voltage |
12-Volts
DC nominal |
|
| |
Access
Control Max. Current Draw |
1
Amp |
|
| |
Maximum
Electrical Cabling Distance |
200
metres |
|
| |
Optional
Integrated Access Control |
Radio
remote Key Fob |
|
| |
|
|
|